Home | << 1 2 >> |
![]() |
Aiyangar, A. K., Vivanco, J., Au, A. G., Anderson, P. A., Smith, E. L., & Ploeg, H. L. (2014). Dependence of Anisotropy of Human Lumbar Vertebral Trabecular Bone on Quantitative Computed Tomography-Based Apparent Density. J. Biomech. Eng.-Trans. ASME, 136(9), 10 pp.
Abstract: Most studies investigating human lumbar vertebral trabecular bone (HVTB) mechanical property-density relationships have presented results for the superior-inferior (SI), or “ on-axis” direction. Equivalent, directly measured data from mechanical testing in the transverse (TR) direction are sparse and quantitative computed tomography (QCT) density-dependent variations in the anisotropy ratio of HVTB have not been adequately studied. The current study aimed to investigate the dependence of HVTB mechanical anisotropy ratio on QCT density by quantifying the empirical relationships between QCT-based apparent density of HVTB and its apparent compressive mechanical propertieselastic modulus (E-app), yield strength (sigma(y)), and yield strain (epsilon(y))-in the SI and TR directions for future clinical QCT-based continuum finite element modeling of HVTB. A total of 51 cylindrical cores (33 axial and 18 transverse) were extracted from four L1 human lumbar cadaveric vertebrae. Intact vertebrae were scanned in a clinical resolution computed tomography (CT) scanner prior to specimen extraction to obtain QCT density, rho(CT). Additionally, physically measured apparent density, computed as ash weight over wet, bulk volume, rho(app), showed significant correlation with rho(CT) [rho(CT) = 1.0568 x rho(app), r = 0.86]. Specimens were compression tested at room temperature using the Zetos bone loading and bioreactor system. Apparent elastic modulus (E-app) and yield strength (sigma(y)) were linearly related to the rho(CT) in the axial direction [E-SI = 1493.8 x (rho(CT)), r = 0.77, p < 0.01; sigma(Y,SI) = 6.9 x (rho(CT)) = 0.13, r = 0.76, p < 0.01] while a power-law relation provided the best fit in the transverse direction [E-TR 3349.1 x (rho(CT))(1.94), r = 0.89, p < 0.01; sigma(Y,TR) 18.81 x (rho(CT)) 1.83, r = 0.83, p < 0.01]. No significant correlation was found between epsilon(y) and rho(CT) in either direction. E-app and sigma(y) in the axial direction were larger compared to the transverse direction by a factor of 3.2 and 2.3, respectively, on average. Furthermore, the degree of anisotropy decreased with increasing density. Comparatively, epsilon(y) exhibited only a mild, but statistically significant anisotropy: transverse strains were larger than those in the axial direction by 30%, on average. Ability to map apparent mechanical properties in the transverse direction, in addition to the axial direction, from CT-based densitometric measures allows incorporation of transverse properties in finite element models based on clinical CT data, partially offsetting the inability of continuum models to accurately represent trabecular architectural variations.
|
Baier, R. V., Raggio, J. I. C., Arancibia, C. T., Bustamante, M., Perez, L., Burda, I., et al. (2021). Structure-function assessment of 3D-printed porous scaffolds by a low-cost/ open source fused filament fabrication printer. Mater. Sci. Eng. C-Mater. Biol. Appl., 123, 111945.
Abstract: Additive manufacturing encompasses a plethora of techniques to manufacture structures from a computational model. Among them, fused filament fabrication (FFF) relies on heating thermoplastics to their fusion point and extruding the material through a nozzle in a controlled pattern. FFF is a suitable technique for tissue engineering, given that allows the fabrication of 3D-scaffolds, which are utilized for tissue regeneration purposes. The objective of this study is to assess a low-cost/open-source 3D printer (In-House), by manufacturing both solid and porous samples with relevant microarchitecture in the physiological range (100?500 ?m pore size), using an equivalent commercial counterpart for comparison. For this, compressive tests in solid and porous scaffolds manufactured in both printers were performed, comparing the results with finite element analysis (FEA) models. Additionally, a microarchitectural analysis was done in samples from both printers, comparing the measurements of both pore size and porosity to their corresponding computer-aided design (CAD) models. Moreover, a preliminary biological assessment was performed using scaffolds from our In-House printer, measuring cell adhesion efficiency. Finally, Fourier transform infrared spectroscopy ? attenuated total reflectance (FTIR?ATR) was performed to evaluate chemical changes in the material (polylactic acid) after fabrication in each printer. The results show that the In-House printer achieved generally better mechanical behavior and resolution capacity than its commercial counterpart, by comparing with their FEA and CAD models, respectively. Moreover, a preliminary biological assessment indicates the feasibility of the In-House printer to be used in tissue engineering applications. The results also show the influence of pore geometry on mechanical properties of 3D-scaffolds and demonstrate that properties such as the apparent elastic modulus (Eapp) can be controlled in 3D-printed scaffolds.
|
Baler, R. V., Wijnhoven, I. B., del Valle, V. I., Giovanetti, C. M., & Vivanco, J. F. (2019). Microporosity Clustering Assessment in Calcium Phosphate Bioceramic Particles. Front. Bioeng. Biotechnol., 7(281), 7 pp.
Abstract: There has been an increase in the application of different biomaterials to repair hard tissues. Within these biomaterials, calcium phosphate (CaP) bioceramics are suitable candidates, since they can be biocompatible, biodegradable, osteoinductive, and osteoconductive. Moreover, during sintering, bioceramic materials are prone to form micropores and undergo changes in their surface topographical features, which influence cellular physiology and bone ingrowth. In this study, five geometrical properties from the surface of CaP bioceramic particles and their micropores were analyzed by data mining techniques, driven by the research question: what are the geometrical properties of individual micropores in a CaP bioceramic, and how do they relate to each other? The analysis not only shows that it is feasible to determine the existence of micropore clusters, but also to quantify their geometrical properties. As a result, these CaP bioceramic particles present three groups of micropore clusters distinctive by their geometrical properties. Consequently, this new methodological clustering assessment can be applied to advance the knowledge about CaP bioceramics and their role in bone tissue engineering.
|
Burgers, T. A., Vivanco, J. F., Zahatnansky, J., Moren, A. J. V., Mason, J. J., & Williams, B. O. (2016). Mice with a heterozygous Lrp6 deletion have impaired fracture healing. Bone Res., 4, 9 pp.
Abstract: Bone fracture non-unions, the failure of a fracture to heal, occur in 10%-20% of fractures and are a costly and debilitating clinical problem. The Wnt/beta-catenin pathway is critical in bone development and fracture healing. Polymorphisms of linking low-density lipoprotein receptor-related protein 6 (LRP6), a Wnt-binding receptor, have been associated with decreased bone mineral density and fragility fractures, although this remains controversial. Mice with a homozygous deletion of Lrp6 have severe skeletal abnormalities and are not viable, whereas mice with a heterozygous deletion have a combinatory effect with Lrp5 to decrease bone mineral density. As fracture healing closely models embryonic skeletal development, we investigated the process of fracture healing in mice heterozygous for Lrp6 (Lrp6(+/-)) and hypothesized that the heterozygous deletion of Lrp6 would impair fracture healing. Mid-diaphyseal femur fractures were induced in Lrp6(+/-) mice and wild-type controls (Lrp6(+/+)). Fractures were analyzed using micro-computed tomography (mu CT) scans, biomechanical testing, and histological analysis. Lrp6(+/-) mice had significantly decreased stiffness and strength at 28 days post fracture (PF) and significantly decreased BV/TV, total density, immature bone density, and mature area within the callus on day-14 and -21 PF; they had significantly increased empty callus area at days 14 and 21 PF. Our results demonstrate that the heterozygous deletion of Lrp6 impairs fracture healing, which suggests that Lrp6 has a role in fracture healing.
|
Collins, C. J., Vivanco, J. F., Sokn, S. A., Williams, B. O., Burgers, T. A., & Ploeg, H. L. (2015). Fracture healing in mice lacking Pten in osteoblasts: a micro-computed tomography image-based analysis of the mechanical properties of the femur. J. Biomech., 48(2), 310–317.
Abstract: In the United States, approximately eight million osseous fractures are reported annually, of which 5-10% fail to create a bony union. Osteoblast-specific deletion of the gene Pten in mice has been found to stimulate bone growth and accelerate fracture healing. Healing rates at four weeks increased in femurs from Pten osteoblast conditional knock-out mice (Pten-CKO) compared to wild-type mice (WT) of the same genetic strain as measured by an increase in mechanical stiffness and failure load in four-point bending tests. Preceding mechanical testing, each femur was imaged using a Skyscan 1172 micro-computed tomography (mu CT) scanner (Skyscan, Kontich, Belgium). The present study used μCT image-based analysis to test the hypothesis that the increased femoral fracture force and stiffness in Pten-CKO were due to greater section properties with the same effective material properties as that of the WT. The second moment of area and section modulus were computed in ImageJ 1.46 (National Institutes of Health) and used to predict the effective flexural modulus and the stress at failure for fourteen pairs of intact and callus WT and twelve pairs of intact and callus Pten-CKO femurs. For callus and intact femurs, the failure stress and tissue mineral density of the Pten-CKO and WT were not different; however, the section properties of the Pten-CKO were more than twice as large 28 days post-fracture. It was therefore concluded, when the gene Pten was conditionally knocked-out in osteoblasts, the resulting increased bending stiffness and force to fracture were due to increased section properties. (C) 2014 Elsevier Ltd. All rights reserved.
|
Contreras-Raggio, J. I., Arancibia, C. T., Millan, C., Ploeg, H. L., Aiyangar, A., & Vivanco, J. F. (2022). Height-to-Diameter Ratio and Porosity Strongly Influence Bulk Compressive Mechanical Properties of 3D-Printed Polymer Scaffolds. Polymers, 14(22), 5017.
Abstract: Although the architectural design parameters of 3D-printed polymer-based scaffolds-porosity, height-to-diameter (H/D) ratio and pore size-are significant determinants of their mechanical integrity, their impact has not been explicitly discussed when reporting bulk mechanical properties. Controlled architectures were designed by systematically varying porosity (30-75%, H/D ratio (0.5-2.0) and pore size (0.25-1.0 mm) and fabricated using fused filament fabrication technique. The influence of the three parameters on compressive mechanical properties-apparent elastic modulus E-app, bulk yield stress sigma(y) and yield strain epsilon(y)-were investigated through a multiple linear regression analysis. H/D ratio and porosity exhibited strong influence on the mechanical behavior, resulting in variations in mean E-app of 60% and 95%, respectively. sigma(y) was comparatively less sensitive to H/D ratio over the range investigated in this study, with 15% variation in mean values. In contrast, porosity resulted in almost 100% variation in mean sigma(y) values. Pore size was not a significant factor for mechanical behavior, although it is a critical factor in the biological behavior of the scaffolds. Quantifying the influence of porosity, H/D ratio and pore size on bench-top tested bulk mechanical properties can help optimize the development of bone scaffolds from a biomechanical perspective.
Keywords: polymer scaffolds; 3D printing; height; diameter ratio; porosity; pore size; mechanical properties
|
Garcia-Huidobro, M. R., Poupin, M. J., Urrutia, C., Rodriguez-Navarro, A. B., Grenier, C., Vivanco, J. F., et al. (2021). An intrapopulational study of organic compounds and biomechanical properties of the shell of the Antarctic bivalve Laternula elliptica (P. P. King, 1832) at King George Island. Polar Biol., 44, 1343–1352.
Abstract: Laternula elliptica is a key bivalve species and widely distributed around the Antarctic continent. This bivalve has been the study subject in several studies centered on ecological, physiological, biochemical, and behavioral patterns. However, little is known about the chemistry and the biomechanical properties of the shells of this mollusk. Here, we present the first report of the intra-population variability in the organic composition and mechanical properties of L. elliptica shells. Further, we analyze different morphological traits and their association with the metabolism of a population of L. elliptica from King George Island, Western Antarctic Peninsula. The summer metabolic rates and the hepatosomatic index values indicate good health conditions of this clam's population. Shell periostracum chemistry is quite similar to bivalves from temperate regions, but the relative amount of protein increased ca. five-fold in shells of L. elliptica. The microhardness is approximately 32% lower than in bivalves from temperate regions. Our characterization of the L. elliptica shells suggests that periostracum chemistry could be specially fitted to avoid shell carbon exposure to dissolution (e.g., in corrosive acidified seawater). In contrast, the reduction in shell hardness may result from prioritizing behavioral (burial) and shell repairing strategies to confront biological (predators) and physical disturbances (e.g., ice scouring). Similar studies in other Antarctic mollusks will help understand the role of shell structure and function in confronting projected climate changes in the Antarctic ocean.
|
Labra, F. A., San Martin, V. A., Jahnsen-Guzman, N., Fernandez, C., Zapata, J., Garcia-Huidobro, M. R., et al. (2022). Metabolic rate allometry in intertidal mussels across environmental gradients: The role of coastal carbonate system parameters in mediating the effects of latitude and temperature. Mar. Pollut. Bull., 184, 114149.
Abstract: We assess the role of direct and indirect effects of coastal environmental drivers (including the parameters of the carbonate system) on energy expenditure (MR) and body mass (M) of the intertidal mussel, Perumytilus pur-puratus, across 10 populations distributed over 2800 km along the Southern Eastern Pacific (SEP) coast. We find biogeographic and local variation in carbonate system variables mediates the effects of latitude and temperature on metabolic rate allometry along the SEP coast. Also, the fitted Piecewise Structural Equation models (PSEM) have greater predictive ability (conditional R2 = 0.95) relative to the allometric scaling model (R2 = 0.35). The largest standardized coefficients for MR and M were determined by the influence of temperature and latitude, followed by pCO2, pH, total alkalinity, and salinity. Thus, physiological diversity of P. purpuratus along the SEP coast emerges as the result of direct and indirect effects of biogeographic and local environmental variables.
|
Lagos, N. A., Benitez, S., Grenier, C., Rodriguez-Navarro, A. B., Garcia-Herrera, C., Abarca-Ortega, A., et al. (2021). Plasticity in organic composition maintains biomechanical performance in shells of juvenile scallops exposed to altered temperature and pH conditions. Sci. Rep., 11(1), 24201.
Abstract: The exposure to environmental variations in pH and temperature has proven impacts on benthic ectotherms calcifiers, as evidenced by tradeoffs between physiological processes. However, how these stressors affect structure and functionality of mollusk shells has received less attention. Episodic events of upwelling of deep cold and low pH waters are well documented in eastern boundary systems and may be stressful to mollusks, impairing both physiological and biomechanical performance. These events are projected to become more intense, and extensive in time with ongoing global warming. In this study, we evaluate the independent and interactive effects of temperature and pH on the biomineral and biomechanical properties of Argopecten purpuratus scallop shells. Total organic matter in the shell mineral increased under reduced pH (similar to 7.7) and control conditions (pH similar to 8.0). The periostracum layer coating the outer shell surface showed increased protein content under low pH conditions but decreasing sulfate and polysaccharides content. Reduced pH negatively impacts shell density and increases the disorder in the orientation of calcite crystals. At elevated temperatures (18 degrees C), shell microhardness increased. Other biomechanical properties were not affected by pH/temperature treatments. Thus, under a reduction of 0.3 pH units and low temperature, the response of A. purpuratus was a tradeoff among organic compounds (biopolymer plasticity), density, and crystal organization (mineral plasticity) to maintain shell biomechanical performance, while increased temperature ameliorated the impacts on shell hardness. Biopolymer plasticity was associated with ecophysiological performance, indicating that, under the influence of natural fluctuations in pH and temperature, energetic constraints might be critical in modulating the long-term sustainability of this compensatory mechanism.
|
Leiva, V., Ruggeri, F., Saulo, H., & Vivanco, J. F. (2017). A methodology based on the Birnbaum-Saunders distribution for reliability analysis applied to nano-materials. Reliab. Eng. Syst. Saf., 157, 192–201.
Abstract: The Birnbaum-Saunders distribution has been widely studied and applied to reliability studies. This paper proposes a novel use of this distribution to analyze the effect on hardness, a material mechanical property, when incorporating nano-particles inside a polymeric bone cement. A plain variety and two modified types of mesoporous silica nano-particles are considered. In biomaterials, one can study the effect of nano-particles on mechanical response reliability. Experimental data collected by the authors from a micro-indentation test about hardness of a commercially available polymeric bone cement are analyzed. Hardness is modeled with the Birnbaum-Saunders distribution and Bayesian inference is performed to derive a methodology, which allows us to evaluate the effect of using nano-particles at different loadings by the R software. (C) 2016 Elsevier Ltd. All rights reserved.
|
Marchant, C., Leiva, V., Cysneiros, F. J. A., & Vivanco, J. F. (2016). Diagnostics in multivariate generalized Birnbaum-Saunders regression models. J. Appl. Stat., 43(15), 2829–2849.
Abstract: Birnbaum-Saunders (BS) models are receiving considerable attention in the literature. Multivariate regression models are a useful tool of the multivariate analysis, which takes into account the correlation between variables. Diagnostic analysis is an important aspect to be considered in the statistical modeling. In this paper, we formulate multivariate generalized BS regression models and carry out a diagnostic analysis for these models. We consider the Mahalanobis distance as a global influence measure to detect multivariate outliers and use it for evaluating the adequacy of the distributional assumption. We also consider the local influence approach and study how a perturbation may impact on the estimation of model parameters. We implement the obtained results in the R software, which are illustrated with real-world multivariate data to show their potential applications.
|
Martel, S. I., Fernandez, C., Lagos, N. A., Labra, F. A., Duarte, C., Vivanco, J. F., et al. (2022). Acidification and high-temperature impacts on energetics and shell production of the edible clam Ameghinomya antiqua. Front. Mar. Sci., 9, 972135.
Abstract: Warming and ocean acidification are currently critical global change drivers for marine ecosystems due to their complex and irreversible effects on the ecology and evolution of marine communities. Changes in the chemistry and the temperature of the ocean impact the biological performance of marine resources by affecting their energy budget and thus imposing energetic restrictions and trade-offs on their survival, growth, and reproduction. In this study, we evaluated the interplaying effects of increased pCO(2) levels and temperature on the economically relevant clam Ameghinomya antiqua, an infaunal bivalve inhabiting a wide distributional range along the coast of Chile. Juvenile clams collected from southern Chile were exposed to a 90-day experimental set-up emulating the current and a future scenario projeced to the end of the current century for both high pCO(2)/low-pH and temperature (10 and 15 degrees C) projected for the Chilean coast. Clams showed physiological plasticity to different projected environmental scenarios without mortality. In addition, our results showed that the specimens under low-pH conditions were not able to meet the energetic requirements when increased temperature imposed high maintenance costs, consequently showing metabolic depression. Indeed, although the calcification rate was negative in the high-pCO(2) scenario, it was the temperature that determined the amount of shell loss. These results indicate that the studied clam can face environmental changes for short-term periods modifying energetic allocation on maintenance and growth processes, but with possible long-term population costs, endangering the sustainability of an important benthic artisanal fisheries resource.
|
Meyer, L. A., Johnson, M. G., Cullen, D. M., Vivanco, J. F., Blank, R. D., Ploeg, H. L., et al. (2016). Combined exposure to big endothelin-1 and mechanical loading in bovine sternal cores promotes osteogenesis. Bone, 85, 115–122.
Abstract: Increased bone formation resulting from mechanical loading is well documented; however, the interactions of the mechanotransduction pathways are less well understood. Endothelin-1, a ubiquitous autocrine/paracrine signaling molecule promotes osteogenesis in metastatic disease. In the present study, it was hypothesized that exposure to big endothelin-1 (big ET1) and/or mechanical loading would promote osteogenesis in ex vivo trabecular bone cores. In a 2 x 2 factorial trial of daily mechanical loading (-2000 μepsilon,120 cycles daily, “jump” waveform) and big ET1 (25 ng/mL), 48 bovine sternal trabecular bone cores were maintained in bioreactor chambers for 23 days. The bone cores' response to the treatment stimuli was assessed with percent change in core apparent elastic modulus (Delta E-app), static and dynamic histomorphometry, and prostaglandin E2 (PGE2) secretion. Two-way ANOVA with a post hoc Fisher's LSD test found no significant treatment effects on Delta E-app (p = 0.25 and 0.51 for load and big ET1, respectively). The Delta E-app in the “no load + big ET1” (CE, 13 +/- 12.2%, p = 0.56), “load + no big ET1” (LC, 17 +/- 3.9%, p = 0.14) and “load + big ETI” (LE, 19 +/- 4.2%, p = 0.13) treatment groups were not statistically different than the control group (CC, 3.3% +/- 8.6%). Mineralizing surface (MS/BS), mineral apposition (MAR) and bone formation rates (BFR/BS) were significantly greater in LE than CC (p = 0.037, 0.0040 and 0.019, respectively). While the histological bone formation markers in LC trended to be greater than CC (p = 0.055, 0.11 and 0.074, respectively) there was no difference between CE and CC (p = 0.61, 0.50 and 0.72, respectively). Cores in LE and LC had more than 50% greater MS/BS (p = 0.037, p = 0.055 respectively) and MAR (p = 0.0040, p = 0.11 respectively) than CC. The BFR/BS was more than two times greater in LE (p = 0.019) and LC (p = 0.074) than CC. The PGE2 levels were elevated at 8 days post-osteotomy in all groups and the treatment groups remained elevated compared to the CC group on days 15,19 and 23. The data suggest that combined exposure to big ET1 and mechanical loading results in increased osteogenesis as measured in biomechanical, histomorphometric and biochemical responses. (C) 2016 Elsevier Inc. All rights reserved.
Keywords: Endothelin; Mechanical loading; Trabecular bone; Osteogenesis; Bioreactor
|
Millan, C., Vivanco, J. F., Benjumeda-Wijnhoven, I. M., Bjelica, S., & Santibanez, J. F. (2018). Mesenchymal Stem Cells and Calcium Phosphate Bioceramics: Implications in Periodontal Bone Regeneration. Adv.Exp.Med.Biol., 1107, 91–112.
Abstract: In orthopedic medicine, a feasible reconstruction of bone structures remains one of the main challenges both for healthcare and for improvement of patients' quality of life. There is a growing interest in mesenchymal stem cells (MSCs) medical application, due to their multilineage differentiation potential, and tissue engineering integration to improve bone repair and regeneration. In this review we will describe the main characteristics of MSCs, such as osteogenesis, immunomodulation and antibacterial properties, key parameters to consider during bone repair strategies. Moreover, we describe the properties of calciumphosphate (CaP) bioceramics, which demonstrate to be useful tools in combination with MSCs, due to their biocompatibility, osseointegration and osteoconduction for bone repair and regeneration. Also, we overview the main characteristics of dental cavity MSCs, which are promising candidates, in combination with CaP bioceramics, for bone regeneration and tissue engineering. The understanding of MSCs biology and their interaction with CaP bioceramics and other biomaterials is critical for orthopedic surgical bone replacement, reconstruction and regeneration, which is an integrative and dynamic medical, scientific and bioengineering field of research and biotechnology.
|
Norambuena-Contreras, J., Arteaga-Perez, L. E., Guadarrama-Lezama, A. Y., Briones, R., Vivanco, J. F., & Gonzalez-Torre, I. (2020). Microencapsulated Bio-Based Rejuvenators for the Self-Healing of Bituminous Materials. Materials, 13(6), 16 pp.
Abstract: Asphalt self-healing by encapsulated rejuvenating agents is considered a revolutionary technology for the autonomic crack-healing of aged asphalt pavements. This paper aims to explore the use of Bio-Oil (BO) obtained from liquefied agricultural biomass waste as a bio-based encapsulated rejuvenating agent for self-healing of bituminous materials. Novel BO capsules were synthesized using two simple dripping methods through dropping funnel and syringe pump devices, where the BO agent was microencapsulated by external ionic gelation in a biopolymer matrix of sodium alginate. Size, surface aspect, and elemental composition of the BO capsules were characterized by optical and scanning electron microscopy and energy-dispersive X-ray spectroscopy. Thermal stability and chemical properties of BO capsules and their components were assessed through thermogravimetric analysis (TGA-DTG) and Fourier-Transform Infrared spectroscopy (FTIR-ATR). The mechanical behavior of the capsules was evaluated by compressive and low-load micro-indentation tests. The self-healing efficiency over time of BO as a rejuvenating agent in cracked bitumen samples was quantified by fluorescence microscopy. Main results showed that the BO capsules presented an adequate morphology for the asphalt self-healing application, with good thermal stability and physical-chemical properties. It was also proven that the BO can diffuse in the bitumen reducing the viscosity and consequently self-healing the open microcracks.
|
Norambuena-Contreras, J., Gonzalez-Torre, I., Vivanco, J. F., & Gacitua, W. (2016). Nanomechanical properties of polymeric fibres used in geosynthetics. Polym. Test, 54, 67–77.
Abstract: Geosynthetics are composite materials manufactured using different types of polymeric fibres, usually employed as anti-reflective cracking systems in asphalt pavements. Materials that compose geosynthetics can be damaged due to mechanical and thermal effects produced during the installation process under hot mix asphalts. In this paper, different polymeric fibres extracted from geosynthetics have been evaluated using nanoindentation tests. The main objective was to evaluate the effect of installation process (dynamic compaction and thermal damage) on the mechanical behaviour of individual polymeric fibres at nano-scale. To do this, elastic modulus (E) and hardness (H) of three different polymeric fibres commonly used in geosynthetics (polypropylene, polyester and polyvinyl-alcohol), in two testing directions and under two different states have been studied. Main conclusions of this work are that mechanical properties of geosynthetics individual fibres can change after installation, producing changes in the behaviour of geosynthetics at macro-scale with consequences in the pavement functionality, and that these changes are different depending on the material that composed the fibres. (C) 2016 Elsevier Ltd. All rights reserved.
|
Slane, J., Vivanco, J., Ebenstein, D., Squire, M., & Ploeg, H. L. (2014). Multiscale characterization of acrylic bone cement modified with functionalized mesoporous silica nanoparticles. J. Mech. Behav. Biomed. Mater., 37, 141–152.
Abstract: Acrylic bone cement is widely used to anchor orthopedic implants to bone and mechanical failure of the cement mantle surrounding an implant can contribute to aseptic loosening. In an effort to enhance the mechanical properties of bone cement, a variety of nanoparticles and fibers can be incorporated into the cement matrix. Mesoporous silica nanoparticles (MSNs) are a class of particles that display high potential for use as reinforcement within bone cement. Therefore, the purpose of this study was to quantify the impact of modifying an acrylic cement with various low-loadings of mesoporous silica. Three types of MSNs (one plain variety and two modified with functional groups) at two loading ratios (0.1 and 0.2 wt/wt) were incorporated into a commercially available bone cement. The mechanical properties were characterized using four-point bending, microindentation and nanoindentation (static, stress relaxation, and creep) while material properties were assessed through dynamic mechanical analysis, differential scanning calorimetry, thermogravimetric analysis, FTIR spectroscopy, and scanning electron microscopy. Four-point flexural testing and nanoindentation revealed minimal impact on the properties of the cements, except for several changes in the nano-level static mechanical properties. Conversely, microindentation testing demonstrated that the addition of MSNs significantly increased the microhardness. The stress relaxation and creep properties of the cements measured with nanoindentation displayed no effect resulting from the addition of MSNs. The measured material properties were consistent among all cements. Analysis of scanning electron micrographs images revealed that surface functionalization enhanced particle dispersion within the cement matrix and resulted in fewer particle agglomerates. These results suggest that the loading ratios of mesoporous silica used in this study were not an effective reinforcement material. Future work should be conducted to determine the impact of higher MSN loading ratios and alternative functional groups. (C) 2014 Elsevier Ltd. All rights reserved.
|
Slane, J., Vivanco, J., Meyer, J., Ploeg, H. L., & Squire, M. (2014). Modification of acrylic bone cement with mesoporous silica nanoparticles: Effects on mechanical, fatigue and absorption properties. J. Mech. Behav. Biomed. Mater., 29, 451–461.
Abstract: Polymethyl methacrylate bone cement is the most common and successful method used to anchor orthopedic implants to bone, as evidenced by data from long-term national joint registries. Despite these successes, mechanical failure of the cement mantle can result in premature failure of an implant which has lead to the development of a variety of techniques aimed at enhancing the mechanical properties of the cement, such as the addition of particulate or fiber reinforcements. This technique however has not transitioned into clinical practice, likely due to problems relating to interfacial particle/matrix adhesion and high cement stiffness. Mesoporous silica nanoparticles (MSNs) are a class of materials that have received little attention as polymer reinforcements despite their potential ability to overcome these challenges. Therefore, the objective of the present study was to investigate the use of mesoporous silica nanoparticles (MSNs) as a reinforcement material within acrylic bone cement. Three different MSN loading ratios (0.5%, 2% and 5% (wt/wt)) were incorporated into a commercially available bone cement and the resulting impact on the cement's static mechanical properties, fatigue life and absorption/elution properties were quantified. The flexural modulus and compressive strength and modulus tended to increase with higher MSN concentration. Conversely, the flexural strength, fracture toughness and work to fracture all significantly decreased with increasing MSN content. The fatigue properties were found to be highly influenced by MSNs, with substantial detrimental effects seen with high MSN loadings. The incorporation of 5% MSNs significantly increased cement's hydration degree and elution percentage. The obtained results suggest that the interfacial adhesion strength between the nanoparticles and the polymer matrix was poor, leading to a decrease in the flexural and fatigue properties, or that adequate dispersion of the MSNs was not achieved. These findings could potentially be mitigated in future work by chemically modifying the mesoporous silica with functional groups. (C) 2013 Elsevier Ltd. All rights reserved.
|
Slane, J., Vivanco, J., Rose, W., Ploeg, H. L., & Squire, M. (2015). Mechanical, material, and antimicrobial properties of acrylic bone cement impregnated with silver nanoparticles. Mater. Sci. Eng. C-Mater. Biol. Appl., 48, 188–196.
Abstract: Prosthetic joint infection is one of the most serious complications that can lead to failure of a total joint replacement. Recently, the rise of multidrug resistant bacteria has substantially reduced the efficacy of antibiotics that are typically incorporated into acrylic bone cement. Silver nanoparticles (AgNPs) are an attractive alternative to traditional antibiotics resulting from their broad-spectrum antimicrobial activity and low bacterial resistance. The purpose of this study, therefore, was to incorporate metallic silver nanoparticles into acrylic bone cement and quantify the effects on the cement's mechanical, material and antimicrobial properties. AgNPs at three loading ratios (025, 0.5, and 1.0% wt/wt) were incorporated into a commercial bone cement using a probe sonication technique. The resulting cements demonstrated mechanical and material properties that were not substantially different from the standard cement. Testing against Staphylococcus aureus and Staphylococcus epidermidis using Kirby-Bauer and time-kill assays demonstrated no antimicrobial activity against planktonic bacteria. In contrast, cements modified with AgNPs significantly reduced biofilm formation on the surface of the cement. These results indicate that AgNP-loaded cement is of high potential for use in primary arthroplasty where prevention of bacterial surface colonization is vital. (C) 2014 Elsevier B.V. All rights reserved.
Keywords: Bone cement; Infection; Nanoparticles; Antimicrobial; Mechanical properties
|
Slane, J., Vivanco, J. F., Squire, M., & Ploeg, H. L. (2017). Characterization of the quasi-static and viscoelastic properties of orthopaedic bone cement at the macro and nanoscale. J. Biomed. Mater. Res. Part B, 105(6), 1461–1468.
Abstract: Acrylic bone cement is often used in total joint replacement procedures to anchor an orthopaedic implant to bone. Bone cement is a viscoelastic material that exhibits creep and stress relaxation properties, which have been previously characterized using a variety of techniques such as flexural testing. Nanoindentation has become a popular method to characterize polymer mechanical properties at the nanoscale due to the technique's high sensitivity and the small sample volume required for testing. The purpose of the present work therefore was to determine the mechanical properties of bone cement using traditional macroscale techniques and compare the results to those obtained from nanoindentation. To this end, the quasi-static and viscoelastic properties of two commercially available cements, Palacos and Simplex, were assessed using a combination of three-point bending and nanoindentation. Quasi-static properties obtained from nanoindentation tended to be higher relative to three-point bending. The general displacement and creep compliance trends were similar for the two methods. These findings suggest that nanoindentation is an attractive characterization technique for bone cement, due to the small sample volumes required for testing. This may prove particularly useful in testing failed/ retrieved cement samples from patients where material availability is typically limited. (C) 2016 Wiley Periodicals, Inc.
Keywords: bone cement; nanoindentation; mechanical testing; creep; orthopaedics
|